File
Authors
Inada, Takashi
Sodani, Yuta
Li, Shigang
Keywords
biometrics
intra-palm propagation signal
SVM
Abstract
The use of intra-palm propagation signals as biometrics is proposed. The intra-palm propagation signal is an electromagnetic wave propagated in the palm. In this study, intra-palm propagation signals are measured using dedicated measuring devices and their verification performance based on the Support Vector Machine is evaluated using twenty-one subjects. The equal error rate is approximately 25 %.
Publisher
IEEE
Content Type
Conference Paper
Link
ISSN・ISBN
9780769550190
Journal Title
Proceedings of 2013 International Conference on Biometrics and Kansei Engineering (ICBAKE2013)
Current Journal Title
Proceedings of 2013 International Conference on Biometrics and Kansei Engineering (ICBAKE2013)
Start Page
91
End Page
94
Published Date
2013
Publisher-DOI
Text Version
Author
Rights
© © 2013 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
Citation
Proceedings of 2013 International Conference on Biometrics and Kansei Engineering (ICBAKE2013). 2017, 91-94
Department
Faculty of Engineering/Graduate School of Engineering
Language
English