フルテキストファイル
著者
Minami Yukari Department of Surgery, Division of Anesthesiology and Critical Care Medicine, Tottori University Faculty of Medicine 研究者総覧 KAKEN
Liu Renyu Department of Anesthesia, University of Pennsylvania Medical Center
Ishibe Yuichi Department of Surgery, Division of Anesthesiology and Critical Care Medicine, Tottori University Faculty of Medicine
Okazaki Naoto Department of Surgery, Division of Anesthesiology and Critical Care Medicine, Tottori University Faculty of Medicine
Funakoshi Tae Department of Surgery, Division of Anesthesiology and Critical Care Medicine, Tottori University Faculty of Medicine KAKEN
Ueda Keiichiro Department of Surgery, Division of Anesthesiology and Critical Care Medicine, Tottori University Faculty of Medicine
キーワード
exhaled nitric oxide
one lung ventilation
online measurement
simulator
thoracic surgery
抄録
Measurement of exhaled nitric oxide (NO) has been gaining much interest lately. However, an ideal measuring system is not yet available in the clinical setting. The aims of the present study were to construct an exhaled NO measuring system and to investigate the effects of one lung ventilation (OLV) on exhaled NO output in patients who underwent thoracic surgery. At first, the NO measuring system was constructed with an NO analyzer, a respiratory flowmeter and a data processing computer system in which the algorithm was indwelled for correcting the distorted NO output wave form. Then, accuracy of this system was tested by using a simulator. This simulator was reworked in order to simulate NO production from the lung under both spontaneous respiration and mechanical ventilation. The data of peak NO concentration (pNO) and NO output (VNO) obtained with the NO monitoring system were significantly correlated with "alveolar" NO concentration (aNO) and exhaled NO volume from the simulator. Then, exhaled NO was measured in 12 thoracic surgery patients who underwent OLV using this system. pNO and VNO were significantly decreased by about half during OLV, and returned to baseline 25 min after releasing OLV. These data suggest that the newly designed online exhaled NO measuring system accurately detected aNO and exhaled NO volume in a breath-by-breath manner, and OLV for about 3 h did not influence the NO output from the lung after releasing OLV in thoracic surgery patients.
出版者
Tottori University Faculty of Medicine
資料タイプ
学術雑誌論文
ISSN
1346-8049
書誌ID
AA00892882
掲載誌名
Yonago Acta medica
最新掲載誌名
Yonago Acta medica
46
4
開始ページ
133
終了ページ
144
発行日
2003-12
著者版フラグ
出版社版
著作権表記
Yonago Acta medica 編集委員会
掲載情報
Yonago Acta medica. 2003, 46(4), 133-144
部局名
医学部・医学系研究科・医学部附属病院
言語
英語