activated partial thromboplastin time
clot waveform
emicizumab
hemophilia A
抄録
Background Clot waveform analysis (CWA) based on activated partial thromboplastin time (APTT) is a useful assay for hemostasis. However, the effects of activators and phospholipid conditions on CWA have not been adequately investigated. Therefore, we characterized CWA using four different APTT reagents. Methods: We used 39 archived plasma samples from patients with hemophilia A (HA), 16 samples from patients with HA under emicizumab treatment, and 10 samples from healthy individuals for CWA with four different types of APTT reagents (reagents A, B, C, and D). We then compared Ad|min1|, Ad|min2|, and Ad|max2| from the CWA, which reflect the maximum velocity, maximum acceleration, and maximum deceleration, respectively, among the four reagents. Results: Similar clot waveform shapes were observed for each reagent in the healthy donor group, HA group, and HA under emicizumab group, and the waveform was different for each target group. Significant changes were found in clotting time (CT) (s), Ad|min1| (%/s), Ad|min2| (%/s2), and Ad|max2| (%/s2). The waveform pattern for the coagulation reaction by reagent D, comprising silica and synthetic phospholipids, was the fastest among the reagents examined. Further, the difference in Ad|min1| (%/s) and Ad|min2| (%/s2) was larger than that in CT depending on the reagent used(s), indicating that the measured value of CWA was affected by the reagent composition. Conclusion: Our results showed a significant difference among reagents with varying composition and concentration; this was found to affect the parameters obtained from CWA. Thus, the differences between reagents hinder standardization of quantitative evaluation using these parameters; further, this highlights the necessity of understanding the characteristics of APTT reagents and determining the reference range in individual facilities.
出版者
Tottori University Medical Press
資料タイプ
学術雑誌論文
外部リンク
ISSN
05135710
EISSN
13468049
書誌ID
AA00892882
掲載誌名
Yonago Acta Medica
最新掲載誌名
Yonago Acta Medica
65
3
開始ページ
226
終了ページ
230
発行日
2022-08-29
出版者DOI
著者版フラグ
出版社版
著作権表記
(C) 2022 Tottori University Medical Press.
掲載情報
Yonago Acta Medica. 2022, 65(3), 226-230. doi10.33160/yam.2022.08.013
部局名
医学部・医学系研究科・医学部附属病院
言語
英語