フルテキストファイル
著者
松末 英司 Department of Radiology, Tottori Prefectural Central Hospital KAKEN
井上 千恵 Department of Radiology, Tottori Prefectural Central Hospital
Matsumoto, Kensuke Department of Radiology, Tottori Prefectural Central Hospital
谷野 朋彦 Department of Radiology, Tottori Prefectural Central Hospital 研究者総覧
Nakamura, Kazuhiko Department of Radiology, Tottori Prefectural Central Hospital
藤井 進也 Division of Radiology, Department of Multidisciplinary Internal Medicine, School of Medicine, Tottori University 研究者総覧 KAKEN
キーワード
cochlear modiolus
magnetic resonance imaging
superficial siderosis
T1-shortening
SPGR
抄録
Background: Superficial siderosis (SS) results from chronic bleeding in the subarachnoid space. SS can be classified as infratentorial SS (i-SS) and supratentorial SS (s-SS). The cochlear modiolus (CM) normally shows low signal intensity (SI) on Tl-weighted images (T1WI). We noticed persistently high SI of the CM on unenhanced thin-sliced T1WI in patients with i-SS. The purpose of this study was to evaluate the correlation between SS and high SI of the CM on unenhanced T1WI. Methods: This retrospective study analyzed three cases with i-SS, eight cases with s-SS, and 23 normal controls (NC) evaluated on unenhanced thin-sliced T1WI with a three-dimensional spoiled gradient-recalled echo sequence. CM-T1SI scores of 0, 1, and 2 indicated low, iso, and high SI, respectively. In cases with scores of 2 evaluated several times, all scores were reviewed for each case. The CM-T1SI ratio was defined as the contrast ratio between the CM and the cerebellum. Differences between the three groups were statistically analyzed based on the CM-T1SI score and ratio. Receiver operative curve (ROC) analysis was used to determine the cut-off values for differentiating the i-SS group from the NC group based on the CM-T1SI ratio. Results: Two patients with i-SS had a score of 2 on all evaluations. The CM-T1SI score and ratio differed significantly between the i-SS and NC groups. The accuracy of the CM-T1SI ratio for discriminating i-SS from NC was 98.9% at a cutoff value of 0.628. Conclusion: High SI of the CM on unenhanced TIWI can be an additional characteristic finding of i-SS.
出版者
Tottori University Medical Press
資料タイプ
学術雑誌論文
外部リンク
ISSN
05135710
EISSN
13468049
書誌ID
AA00892882
掲載誌名
Yonago Acta Medica
最新掲載誌名
Yonago Acta Medica
65
4
開始ページ
270
終了ページ
277
発行日
2022-11-28
出版者DOI
著者版フラグ
出版社版
著作権表記
(C) 2022 Tottori University Medical Press.
掲載情報
Yonago Acta Medica. 2022, 65(4), 270-277. doi10.33160/yam.2022.11.001
部局名
医学部・医学系研究科・医学部附属病院
言語
英語