EG-580UT
endoscopic ultrasonography
EU-ME2
GF-UCT260
SU-1
抄録
[Background] Although endoscopic ultrasonography (EUS) is a useful tool for diagnosing pancreatobiliary diseases, not many facilities perform this technique as it is difficult to master. Currently, two new EUS systems exist: EU-ME2/GF-UCT260, manufactured by Olympus, and SU-1/EG-580UT, manufactured by Fujifilm. Some reports have compared new EUS models to older versions, but the operability and image quality of these two latest systems have not been compared. Our study aimed to compare the usefulness of these two types of EUS. [Methods] Forty consecutive patients were recruited and randomized in a two-arm clinical trial; Arm 1: EU-ME2/GF-UCT260 was used only for observation and SU-1/EG-580UT for EUS-fine needle aspiration (FNA); Arm 2: SU-1/EG-580UT was used only for observation and EU-ME2/GF-UCT260 for EUS-FNA. Using a crossover design, we evaluated image findings, ease of scope insertion, and visibility of the gastrointestinal (GI) tract. Each procedure was scored using a 5-point scale (Clinical Trial ID: UMIN000031373). [Results] SU-1/EG-580UT was significantly better in terms of lesion-delineating capacity: lesion border (P < 0.001), internal echo (P < 0.001). Significantly easier scope insertion was observed with SU-1/EG-580UT with respect to any insertion into the piriform recess (P = 0.018), the pylorus ring (P < 0.001), and the superior duodenal angle (P < 0.001). Visibility during gastrointestinal observation was also significantly better with the SU-1/EG-580UT (P < 0.001) than with the EU-ME2/GF-UCT260. [Conclusion] SU-1/EG-580UT EUS demonstrated superior performance during ultrasonic endoscopic GI observation, operability, and ultrasonic image quality. The result of the superior ultrasound imaging quality of SU-1/EG-580UT EUS will aid in the identification of small pancreatic malignancies with unclear borders and prove useful in evaluating mural nodules of IPMN in detail. These findings could result in an increased use of EUS and improve identification and prognosis of patients with pancreatobiliary diseases.
出版者
Tottori University Medical Press
資料タイプ
学術雑誌論文
外部リンク
ISSN
0513-5710
EISSN
1346-8049
書誌ID
AA00892882
掲載誌名
Yonago Acta Medica
最新掲載誌名
Yonago Acta Medica
62
1
開始ページ
94
終了ページ
99
発行日
2019-3-28
出版者DOI
著者版フラグ
出版社版
著作権表記
注があるものを除き、この著作物は日本国著作権法により保護されています。 / This work is protected under Japanese Copyright Law unless otherwise noted.
掲載情報
Yonago Acta Medica. 2019, 62(1), 94-99
部局名
医学部・医学系研究科・医学部附属病院
言語
英語