{"created":"2023-08-02T03:56:05.992860+00:00","id":5081,"links":{},"metadata":{"_buckets":{"deposit":"74574fde-673c-458a-94d2-64b6700ba594"},"_deposit":{"created_by":10,"id":"5081","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"5081"},"status":"published"},"_oai":{"id":"oai:repository.lib.tottori-u.ac.jp:00005081","sets":["1:9","2:12","23:34:1063:1065"]},"author_link":["18782","3186","4359","167","18783","18784","3697","18785","18786","18787"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"62","bibliographicPageStart":"57","bibliographicVolumeNumber":"48","bibliographic_titles":[{"bibliographic_title":"Yonago Acta medica"},{"bibliographic_title":"Yonago Acta medica","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Clinical use of a 3-dimensional ultrasonography system with a new ophthalmic imaging device using conventional 2-dimensional ultrasound tomography in the ophthalmic field was evaluated in 5 patients with different ocular conditions. With the system, surface rendering and volume measurement were easy in 3-dimensional ultrasonographic examinations. In a patient with rhegmatogenous retinal detachment, the surface rendering made the image cube transparent, revealing interior surface details. In a patient with lens luxation resulting from Marfan's syndrome, the shape of luxated spherophakia was detected stereographically. In a patient with choroidal detachment, we could evaluate the effect of administration of aspirin on the amelioration of this disease by measuring the volume of the choroidal lesion. In a patient with aberration of a lens fragment into subretinal space during cataract surgery, we grasped the whole ocular condition in the 3-dimensional image only by just one manipulation. In a patient with optic disc melanocytoma, we could detect the volume change in detail using the 3-dimensional images-saving system. No discomfort occurred in these patients during examination. Based upon the above findings, we considered that this device was useful in making diagnosis and grasping the whole ocular conditions and outcome in breathtaking 3-dimensional views, and in causing no discomfort for patients.","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Tottori University Faculty of Medicine"}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Yonago Acta medica. 2005, 48(2),57-62"}]}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Yonago Acta medica 編集委員会"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00892882","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13468049","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_32":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Clinic of Ophthalmology, Nagasaki Municipal Hospital"},{"subitem_text_value":"Division of Ophthalmology and Visual Science, Department of Medicine of Sensory and Motor Organs, School of Medicine"},{"subitem_text_value":"Division of Ophthalmology and Visual Science, Department of Medicine of Sensory and Motor Organs, School of Medicine"},{"subitem_text_value":"Division of Ophthalmology and Visual Science, Department of Medicine of Sensory and Motor Organs, School of Medicine"},{"subitem_text_value":"Division of Ophthalmology and Visual Science, Department of Medicine of Sensory and Motor Organs, School of Medicine"},{"subitem_text_value":"Division of Ophthalmology and Visual Science, Department of Medicine of Sensory and Motor Organs, School of Medicine"},{"subitem_text_value":"Department of Biomedical Science, Institute of Regenerative Medicine and Biofunction, Tottori University Graduate School of Medical Sciences"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kumagami, Takeshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sasaki, Yuji"},{"creatorName":"Sasaki, Yuji","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Yamasaki, Atsushi"},{"creatorName":"Yamasaki, Atsushi","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Baba, Takashi"},{"creatorName":"Baba, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Hasegawa, Jiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuura, Kazuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamai, Akihiko"},{"creatorName":"Tamai, Akihiko","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Kumagami, Takeshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hasegawa, Jiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuura, Kazuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2009-06-09"}],"displaytype":"detail","filename":"48_057-062.pdf","filesize":[{"value":"187.4 kB"}],"format":"application/pdf","licensefree":"Yonago Acta medica 編集委員会","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"48_057-062.pdf","url":"https://repository.lib.tottori-u.ac.jp/record/5081/files/48_057-062.pdf"},"version_id":"98d6c0be-20be-44ce-8d40-282a45897e2d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"3-dimensional images-saving system","subitem_subject_scheme":"Other"},{"subitem_subject":"3-dimensional ultrasonography system","subitem_subject_scheme":"Other"},{"subitem_subject":"2-dimensional ultrasound tomography","subitem_subject_scheme":"Other"},{"subitem_subject":"surface rendering","subitem_subject_scheme":"Other"},{"subitem_subject":"volume measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"3-dimensional images-saving system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"3-dimensional ultrasonography system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"2-dimensional ultrasound tomography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"surface rendering","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"volume measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article"}]},"item_title":"Clinical Evaluation of a Three-Dimensional Ultrasonography System in the Ophthalmic Field","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Clinical Evaluation of a Three-Dimensional Ultrasonography System in the Ophthalmic Field","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"10","path":["12","9","1065"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-06-22"},"publish_date":"2018-06-22","publish_status":"0","recid":"5081","relation_version_is_last":true,"title":["Clinical Evaluation of a Three-Dimensional Ultrasonography System in the Ophthalmic Field"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2023-10-03T23:53:05.156905+00:00"}