{"created":"2023-08-02T03:58:02.962169+00:00","id":7178,"links":{},"metadata":{"_buckets":{"deposit":"0f0357ca-293e-4159-9019-01fb946dfe3d"},"_deposit":{"created_by":10,"id":"7178","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"7178"},"status":"published"},"_oai":{"id":"oai:repository.lib.tottori-u.ac.jp:00007178","sets":["1:10","2:12"]},"author_link":["587","4701","26566","26567"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"8","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"ENERGIES"},{"bibliographic_title":"ENERGIES","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To investigate the optimum layouts of small vertical-axis wind turbines, a two-dimensional analysis of dynamic fluid body interaction is performed via computational fluid dynamics for a rotor pair in various configurations. The rotational speed of each turbine rotor (diameter: D = 50 mm) varies based on the equation of motion. First, the dependence of rotor performance on the gap distance (gap) between two rotors is investigated. For parallel layouts, counter-down (CD) layouts with blades moving downwind in the gap region yield a higher mean power than counter-up (CU) layouts with blades moving upwind in the gap region. CD layouts with gap/D = 0.5–1.0 yield a maximum average power that is 23% higher than that of an isolated single rotor. Assuming isotropic bidirectional wind speed, co-rotating (CO) layouts with the same rotational direction are superior to the combination of CD and CU layouts regardless of the gap distance. For tandem layouts, the inverse-rotation (IR) configuration shows an earlier wake recovery than the CO configuration. For 16-wind-direction layouts, both the IR and CO configurations indicate similar power distribution at gap/D = 2.0. For the first time, this study demonstrates the phase synchronization of two rotors via numerical simulation","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"MDPI"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3390/en14082286","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Hara Yutaka, Jodai Yoshifumi, Okinaga Tomoyuki, et al. Numerical Analysis of the Dynamic Interaction between Two Closely Spaced Vertical-Axis Wind Turbines. ENERGIES. 2021. 14(8). doi:10.3390/en14082286"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.mdpi.com/1996-1073/14/8/2286"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.mdpi.com/1996-1073/14/8/2286","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(C) 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/)."}]},"item_10001_text_26":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_text_value":"19961073"}]},"item_10001_text_33":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical Engineering, Kagawa National Institute of Technology (KOSEN)"},{"subitem_text_language":"en","subitem_text_value":"Graduate School of Engineering, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Tottori University"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"原, 豊"},{"creatorName":"ハラ, ユタカ","creatorNameLang":"ja-Kana"},{"creatorName":"Hara, Yutaka","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"古川, 勝"},{"creatorName":"フルカワ, マサル","creatorNameLang":"ja-Kana"},{"creatorName":"Furukawa, Masaru","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Jodai, Yoshifumi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okinaga, Tomoyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-17"}],"displaytype":"detail","filename":"enr14(8)_en14082286.pdf","filesize":[{"value":"11.1 MB"}],"format":"application/pdf","licensefree":"(C) 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"enr14(8)_en14082286.pdf","url":"https://repository.lib.tottori-u.ac.jp/record/7178/files/enr14(8)_en14082286.pdf"},"version_id":"bc329b8c-43a2-4791-9eb9-cad701b03693"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"wind energy","subitem_subject_scheme":"Other"},{"subitem_subject":"vertical-axis wind turbine","subitem_subject_scheme":"Other"},{"subitem_subject":"computational fluid dynamics","subitem_subject_scheme":"Other"},{"subitem_subject":"dynamic interaction","subitem_subject_scheme":"Other"},{"subitem_subject":"closely spaced arrangements","subitem_subject_scheme":"Other"},{"subitem_subject":"phase synchronization","subitem_subject_scheme":"Other"},{"subitem_subject":"wind farm","subitem_subject_scheme":"Other"},{"subitem_subject":"dryland","subitem_subject_scheme":"Other"},{"subitem_subject":"wind energy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"vertical-axis wind turbine","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"computational fluid dynamics","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"dynamic interaction","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"closely spaced arrangements","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"phase synchronization","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wind farm","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"dryland","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article"}]},"item_title":"Numerical Analysis of the Dynamic Interaction between Two Closely Spaced Vertical-Axis Wind Turbines","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Numerical Analysis of the Dynamic Interaction between Two Closely Spaced Vertical-Axis Wind Turbines","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"10","path":["12","10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-06-30"},"publish_date":"2022-06-30","publish_status":"0","recid":"7178","relation_version_is_last":true,"title":["Numerical Analysis of the Dynamic Interaction between Two Closely Spaced Vertical-Axis Wind Turbines"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2023-09-29T00:37:46.014693+00:00"}