{"created":"2023-08-02T03:58:04.642006+00:00","id":7215,"links":{},"metadata":{"_buckets":{"deposit":"61feb6d7-b466-4c48-84d8-fcb9306ed04b"},"_deposit":{"created_by":10,"id":"7215","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"7215"},"status":"published"},"_oai":{"id":"oai:repository.lib.tottori-u.ac.jp:00007215","sets":["1:10","2:12"]},"author_link":["2512","26737","26738","26739","26740"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3-4","bibliographicPageEnd":"335","bibliographicPageStart":"321","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"International Journal of Biometrics"},{"bibliographic_title":"International Journal of Biometrics","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Use of intra-body propagation signals has been proposed for biometric authentication. However, verification performance of the conventional method is low. To overcome this limitation, this study introduces the support vector machine (SVM) into the verification process, which improves the verification rate to approximately 83%. However, the correct acceptance rate of genuine users using only SVM is 49%, which is too low for practical applications. Thus, we introduce the concept of one versus one (1vs1) SVM. Each 1vs1 SVM distinguishes a genuine (authorised) user from another (unauthorised) user. Verification is achieved on the basis of a majority rule using plural 1vs1 SVMs related to a genuine user. The correct acceptance rate is greatly improved to 84% while maintaining equivalent verification performance. As a result, it is further confirmed that an intra-body propagation signal is a potential new biometric trait.","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Inderscience"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1504/IJBM.2013.055968","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"International Journal of Biometrics. 2013, 5(3-4), 321-335"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.inderscienceonline.com/doi/abs/10.1504/IJBM.2013.055968"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.inderscienceonline.com/doi/abs/10.1504/IJBM.2013.055968","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"copyright©2013 Inderscience"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"17558301","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_32":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Graduate School of Engineering, Tottori University"},{"subitem_text_value":"Graduate School of Engineering, Tottori University"},{"subitem_text_value":"Graduate School of Engineering, Tottori University"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakanishi, Isao"},{"creatorName":"Nakanishi, Isao","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"2512","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"80243377","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=80243377"},{"nameIdentifier":"100000543","nameIdentifierScheme":"研究者総覧鳥取大学","nameIdentifierURI":"http://researchers.adm.tottori-u.ac.jp/html/100000543_ja.html"}]},{"creatorNames":[{"creatorName":"Sodani, Yuta"}],"nameIdentifiers":[{"nameIdentifier":"26737","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Li, Shigang"}],"nameIdentifiers":[{"nameIdentifier":"26738","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sodani, Yuta","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26739","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Li, Shigang","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26740","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-05-11"}],"displaytype":"detail","filename":"ijb5(3-4)_321.pdf","filesize":[{"value":"322.9 kB"}],"format":"application/pdf","licensefree":"copyright©2013 Inderscience","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ijb5(3-4)_321.pdf","url":"https://repository.lib.tottori-u.ac.jp/record/7215/files/ijb5(3-4)_321.pdf"},"version_id":"7e3790a8-27a9-4201-95af-7acf7886f19e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"biometrics","subitem_subject_scheme":"Other"},{"subitem_subject":"intra-body propagation signal","subitem_subject_scheme":"Other"},{"subitem_subject":"support vector machine","subitem_subject_scheme":"Other"},{"subitem_subject":"SVM","subitem_subject_scheme":"Other"},{"subitem_subject":"one versus one support vector machine","subitem_subject_scheme":"Other"},{"subitem_subject":"1vs1 SVM","subitem_subject_scheme":"Other"},{"subitem_subject":"correct acceptance rate","subitem_subject_scheme":"Other"},{"subitem_subject":"biometrics","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"intra-body propagation signal","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"support vector machine","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"SVM","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"one versus one support vector machine","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"1vs1 SVM","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"correct acceptance rate","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"User verification based on the support vector machine using intra-body propagation signals","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"User verification based on the support vector machine using intra-body propagation signals","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"10","path":["12","10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-06-22"},"publish_date":"2018-06-22","publish_status":"0","recid":"7215","relation_version_is_last":true,"title":["User verification based on the support vector machine using intra-body propagation signals"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2023-09-29T00:39:40.097317+00:00"}