{"created":"2023-08-02T03:58:06.829389+00:00","id":7263,"links":{},"metadata":{"_buckets":{"deposit":"4a843415-cc2f-400c-908f-8a72965282e7"},"_deposit":{"created_by":10,"id":"7263","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"7263"},"status":"published"},"_oai":{"id":"oai:repository.lib.tottori-u.ac.jp:00007263","sets":["1:10","2:12"]},"author_link":["4860","26949","26950","26951"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicVolumeNumber":"20","bibliographic_titles":[{"bibliographic_title":"JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY"},{"bibliographic_title":"JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, we developed an equi-load biaxial tensile tester and applied it to a series of mechanical tests using specimens obtained from the porcine spinal dura mater. The dural sample exhibited a nonlinear and anisotropic behavior as it was more deformable in the longitudinal direction rather than in the circumferential direction at lower strains; i.e., mechanical response of the longitudinal direction was significantly compliant in the Toe region compared to that of the circumferential direction under 1:1 biaxial stretching. However, we have not observed a significant difference with respect to the resultant strain and Young’s modulus between the longitudinal and circumferential directions at higher strains or in the Linear region. Our results also indicated that the upper thoracic region (T1) was relatively compliant compared to the lumbar region (L), where the failure load was almost equal between them because the dural thickness of T1 was five-fold greater than that of L; i.e., spinal dura mater became stiffer and stronger at further distances from the brain. This shows structural effectiveness and may be preferable to mechanically protect the vulnerable spinal cord from externally applied impact loads.","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"World Scientific"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1142/S0219519420500232","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Tamura Atsutaka, Yano Wataru, Yoshimura Daichi, et al. MECHANICAL CHARACTERIZATION OF SPINAL DURA USING A PD-CONTROLLED BIAXIAL TENSILE TESTER. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY. 2020. 20(5). doi:10.1142/S0219519420500232"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.1142/S0219519420500232"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1142/S0219519420500232","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Electronic version of an article published as JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY. 2020. 20(5). doi:10.1142/S0219519420500232. (C) World Scientific Publishing Company. https://www.worldscientific.com/worldscinet/jmmb"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02195194","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_26":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_text_value":"17936810"}]},"item_10001_text_33":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical and Aerospace Engineering, Graduate School of Engineering, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical Engineering, Graduate School of Sustainability Science, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Mechanical and Physical Engineering, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Mechanical and Physical Engineering, Tottori University"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田村, 篤敬"},{"creatorName":"タムラ, アツタカ","creatorNameLang":"ja-Kana"},{"creatorName":"Tamura, Atsutaka","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Yano, Wataru","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yoshimura, Daichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishikawa, Soichiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-07-01"}],"displaytype":"detail","filename":"jmmb20(5)_S0219519420500232.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensefree":"Electronic version of an article published as JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY. 2020. 20(5). doi:10.1142/S0219519420500232. (C) World Scientific Publishing Company. https://www.worldscientific.com/worldscinet/jmmb","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"jmmb20(5)_S0219519420500232.pdf","url":"https://repository.lib.tottori-u.ac.jp/record/7263/files/jmmb20(5)_S0219519420500232.pdf"},"version_id":"a7496d2c-ab6a-481b-8af7-1576aa8ee570"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Spinal dura mater","subitem_subject_scheme":"Other"},{"subitem_subject":"biaxial stretch","subitem_subject_scheme":"Other"},{"subitem_subject":"proportional-derivative control","subitem_subject_scheme":"Other"},{"subitem_subject":"spinal cord injury","subitem_subject_scheme":"Other"},{"subitem_subject":"cerebrospinal fluid","subitem_subject_scheme":"Other"},{"subitem_subject":"spontaneous CSF leak","subitem_subject_scheme":"Other"},{"subitem_subject":"Spinal dura mater","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"biaxial stretch","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"proportional-derivative control","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"spinal cord injury","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"cerebrospinal fluid","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"spontaneous CSF leak","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article"}]},"item_title":"Mechanical Characterization of Spinal Dura Using a PD-Controlled Biaxial Tensile Tester","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Mechanical Characterization of Spinal Dura Using a PD-Controlled Biaxial Tensile Tester","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"10","path":["12","10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-07-28"},"publish_date":"2022-07-28","publish_status":"0","recid":"7263","relation_version_is_last":true,"title":["Mechanical Characterization of Spinal Dura Using a PD-Controlled Biaxial Tensile Tester"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2023-11-22T01:49:11.269672+00:00"}