{"created":"2023-08-02T03:58:32.214754+00:00","id":7700,"links":{},"metadata":{"_buckets":{"deposit":"73026996-8619-42ed-ad2a-2a120e2f75b9"},"_deposit":{"created_by":10,"id":"7700","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"7700"},"status":"published"},"_oai":{"id":"oai:repository.lib.tottori-u.ac.jp:00007700","sets":["1:9","2:12","23:34:975:1125"]},"author_link":["40890","40891","40892","4050","40893","40894","377","40895","40896","40897","40898","40899"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-05-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"286","bibliographicPageStart":"281","bibliographicVolumeNumber":"66","bibliographic_titles":[{"bibliographic_title":"Yonago Acta Medica"},{"bibliographic_title":"Yonago Acta Medica","bibliographic_titleLang":"en"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"04050","subitem_description_type":"Other"},{"subitem_description":"00377","subitem_description_type":"Other"},{"subitem_description":"04523","subitem_description_type":"Other"},{"subitem_description":"03694","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background: A drain is often placed in the abdominal cavity for postoperative monitoring and early detection of complications such as rebleeding and pancreatic or bile leaks. Since determining the color of the drainage fluid is subjective, an objective method of judging color is needed. Methods: The hemoglobin concentration of the drainage fluid after gastrointestinal surgery was measured using the Hemato Check Module, a newly developed instrument capable of absorbance analysis with an optical sensor. The correlation between the results and those measured by an existing blood count measuring device (XN3000) was investigated. Results: A total of 215 specimens were analyzed in 43 patients. For the correlation analysis, there was a strong positive correlation with a correlation coefficient of 0.884 (P < 0.001). The Hemato Check Module showed a clear proportional error compared to the XN3000. Conclusion: The Hemato Check Module was a convenient and accurate instrument for measuring hemoglobin concentration in waste fluid to determine the presence of blood.","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Tottori University Medical Press"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.33160/yam.2023.05.020","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Yonago Acta Medica. 2023, 66(2), 281-286. doi10.33160/yam.2023.05.020"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.lib.tottori-u.ac.jp/yam/yam/yam66-2/66-2contents.html"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.lib.tottori-u.ac.jp/yam/yam/yam66-2/66-2contents.html","subitem_relation_type_select":"URI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.33160/yam.2023.05.020"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.33160/yam.2023.05.020","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(C) 2023 Tottori University Medical Press."}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00892882","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05135710","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_26":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_text_value":"13468049"}]},"item_10001_text_33":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Division of Gastrointestinal and Pediatric Surgery, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Division of Gastroenterology and Nephrology, Department of Multidisciplinary Internal Medicine, School of Medicine, Faculty of Medicine, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Advanced Medicine, Innovation and Clinical Research Center, Tottori University Hospital"},{"subitem_text_language":"en","subitem_text_value":"Division of Medical Education, Department of Medical Education, School of Medicine, Faculty of Medicine, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Division of Gastrointestinal and Pediatric Surgery, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Division of Gastrointestinal and Pediatric Surgery, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University"},{"subitem_text_language":"en","subitem_text_value":"Division of Gastrointestinal and Pediatric Surgery, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Miyauchi, Wataru"}],"nameIdentifiers":[{"nameIdentifier":"40890","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujii, Masashi"}],"nameIdentifiers":[{"nameIdentifier":"40891","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saiki, Naofumi"}],"nameIdentifiers":[{"nameIdentifier":"40892","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"植木, 賢"},{"creatorName":"ウエキ, マサル","creatorNameLang":"ja-Kana"},{"creatorName":"Ueki, Masaru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"4050","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"60542256","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=60542256"},{"nameIdentifier":"100000324","nameIdentifierScheme":"研究者総覧鳥取大学","nameIdentifierURI":"http://researchers.adm.tottori-u.ac.jp/html/100000324_ja.html"}]},{"creatorNames":[{"creatorName":"Sawata, Shohei"}],"nameIdentifiers":[{"nameIdentifier":"40893","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Makinoya, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"40894","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤原, 義之"},{"creatorName":"フジワラ, ヨシユキ","creatorNameLang":"ja-Kana"},{"creatorName":"Fujiwara, Yoshiyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"377","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"40314330","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=40314330"},{"nameIdentifier":"100001755","nameIdentifierScheme":"研究者総覧鳥取大学","nameIdentifierURI":"http://researchers.adm.tottori-u.ac.jp/html/100001755_ja.html"}]},{"creatorNames":[{"creatorName":"Miyauchi, Wataru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"40895","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujii, Masashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"40896","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saiki, Naofumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"40897","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sawata, Shohei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"40898","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Makinoya, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"40899","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-07-18"}],"displaytype":"detail","filename":"yam66(2)_281.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensefree":"(C) 2023 Tottori University Medical Press.","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"yam66(2)_281.pdf","url":"https://repository.lib.tottori-u.ac.jp/record/7700/files/yam66(2)_281.pdf"},"version_id":"f8d5c4fe-8977-475b-a910-b04871584071"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"drainage","subitem_subject_scheme":"Other"},{"subitem_subject":"surgical procedures","subitem_subject_scheme":"Other"},{"subitem_subject":"operative","subitem_subject_scheme":"Other"},{"subitem_subject":"postoperative hemorrhage","subitem_subject_scheme":"Other"},{"subitem_subject":"drainage","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"surgical procedures","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"operative","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"postoperative hemorrhage","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Evaluation of the Hemoglobin Concentration in Drainage Fluid After Surgery by Absorbance Spectrophotometry Using an Optical Sensor","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of the Hemoglobin Concentration in Drainage Fluid After Surgery by Absorbance Spectrophotometry Using an Optical Sensor","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"10","path":["12","9","1125"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-07-18"},"publish_date":"2023-07-18","publish_status":"0","recid":"7700","relation_version_is_last":true,"title":["Evaluation of the Hemoglobin Concentration in Drainage Fluid After Surgery by Absorbance Spectrophotometry Using an Optical Sensor"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2023-09-29T00:49:46.897603+00:00"}