Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2021-09-10 |
タイトル |
|
|
タイトル |
Optimal Number of Systematic Biopsy Cores Used in Magnetic Resonance Imaging/Transrectal Ultrasound Fusion Targeted Prostate Biopsy |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Image-guided biopsy |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
magnetic resonance imaging |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
prostate |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
prostatic neoplasms |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
ultrasonography |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
Image-guided biopsy |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
magnetic resonance imaging |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
prostate |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
prostatic neoplasms |
キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
ultrasonography |
資源タイプ |
|
|
資源タイプ |
journal article |
著者 |
Teraoka, Shogo
Honda, Masashi
Shimizu, Ryutaro
Nishikawa, Ryoma
Kimura, Yusuke
Yumioka, Tetsuya
Iwamoto, Hideto
Morizane, Shuichi
Hikita, Katsuya
Takenaka, Atsushi
|
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
著者所属(英) |
|
|
言語 |
en |
|
値 |
Division of Urology, Department of Surgery, School of Medicine, Faculty of Medicine, Tottori University |
抄録 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
[Background] In recent years, the effectiveness of magnetic resonance imaging (MRI)-ultrasound fusion targeted biopsy (MRF-TB) has been widely reported. In this study, we assessed the effect of reduction of the number of systematic biopsy (SB) cores on the cancer detection rate (CDR). [Methods] Patients with a high prostate-specific antigen (PSA) level underwent prostate MRI. The Prostate Imaging-Reporting and Data System version 2 (PI-RADS) was then used to rate the lesions. The inclusion criteria were as follows: (1) PSA level between 4.0 and 30.0 ng/mL and (2) patients with one or more lesions on MRI and a PI-RADS score of 3 or more. All enrolled patients were SB naïve or had a history of one or more prior negative SBs. A total of 104 Japanese met this selection criterion. We have traditionally performed 14-core SB following the MRF-TB. In this study, the CDRs of 10-core SB methods, excluding biopsy results at the center of the base and mid-level on both sides, were compared with those of the conventional biopsy method. [Results] We compared CDRs of the 14-core and 10-core SBs used in combination. The overall CDR was 55.8% for the former and 55.8% for the latter, thereby indicating that there was no significant difference (P = 1.00) between the two. In addition, the CDRs of csPCa were 51.9% for the former and 51.1% for the latter, which indicated that there was no significant difference (P = 0.317). [Conclusion] There was no significant difference in the CDR when the number of SB cores to be used in combination was 14 and 10. |
書誌情報 |
Yonago Acta Medica
en : Yonago Acta Medica
巻 64,
号 3,
p. 260-268,
発行日 2021-08-24
|
出版者 |
|
|
出版者 |
Tottori University Medical Press |
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
05135710 |
書誌レコードID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00892882 |
DOI |
|
|
関連タイプ |
isIdenticalTo |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.33160/yam.2021.08.004 |
権利 |
|
|
権利情報 |
(C) 2021 Tottori University Medical Press |
情報源 |
|
|
|
関連名称 |
Teraoka Shogo, Honda Masashi, Shimizu Ryutaro, et al. Optimal Number of Systematic Biopsy Cores Used in Magnetic Resonance Imaging/Transrectal Ultrasound Fusion Targeted Prostate Biopsy. Yonago Acta Medica. 2021, 64(3), 260-268. doi:10.33160/yam.2021.08.0 |
関連サイト |
|
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
http://www.lib.tottori-u.ac.jp/yam/yam/yam64-3/64-3contents.html |
|
|
関連名称 |
http://www.lib.tottori-u.ac.jp/yam/yam/yam64-3/64-3contents.html |
関連サイト |
|
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
https://www.jstage.jst.go.jp/article/yam/64/3/64_2021.08.004/_article/-char/en |
|
|
関連名称 |
https://www.jstage.jst.go.jp/article/yam/64/3/64_2021.08.004/_article/-char/en |
著者版フラグ |
|
|
出版タイプ |
VoR |
EISSN |
|
|
値 |
13468049 |