WEKO3
アイテム
Factors Affecting Postoperative Hearing Results in Type IV Tympanoplasty: Preliminary Study of the Influence of External Auditory Canal Packing Material
https://repository.lib.tottori-u.ac.jp/records/4752
https://repository.lib.tottori-u.ac.jp/records/4752fb54f01c-78d8-45ce-82e7-70b46125c0d1
名前 / ファイル | ライセンス | アクション |
---|---|---|
yam63(4)_313.pdf (617.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-12-04 | |||||
タイトル | ||||||
タイトル | Factors Affecting Postoperative Hearing Results in Type IV Tympanoplasty: Preliminary Study of the Influence of External Auditory Canal Packing Material | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | external auditory canal packing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | postoperative hearing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | type IV tympanoplasty | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | external auditory canal packing | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | postoperative hearing | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | type IV tympanoplasty | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
矢間, 敬章
× 矢間, 敬章× 藤原, 和典× 竹内, 裕美× Watanabe, Tasuku |
|||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Division of Otolaryngology, Head and Neck Surgery, Department of Sensory and Motor Organs, School of Medicine, Faculty of Medicine, Tottori University | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Division of Otolaryngology, Head and Neck Surgery, Department of Sensory and Motor Organs, School of Medicine, Faculty of Medicine, Tottori University | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Division of Otolaryngology, Head and Neck Surgery, Department of Sensory and Motor Organs, School of Medicine, Faculty of Medicine, Tottori University | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Division of Otolaryngology, Head and Neck Surgery, Department of Sensory and Motor Organs, School of Medicine, Faculty of Medicine, Tottori University | |||||
抄録 | ||||||
内容記述タイプ | Other | |||||
内容記述 | [Background] Postoperative hearing results of type IV tympanoplasty have been shown to have poorer results than other reconstruction techniques. There are numerous reports evaluating the factors for hearing improvement. This preliminary study aimed to analyze and determine the factors that affect hearing results. [Methods] A total of 80 patients who underwent type IV tympanoplasty were evaluated to participate in this study. The medical records of the candidate patients were collected retrospectively. Fifty out of the 80 recruited patients were excluded due to the following reasons: they could not be followed-up for more than a year after the final operation, their initial surgery was not performed in our department, or they needed a revision surgery. The pre-, intra-, and postoperative factors were evaluated and analyzed using EZR software. Cases were divided into two groups according to postoperative hearing results, and each factor was analyzed univariately. The explanatory variables included in the multivariate analysis were the variables that satisfied P < 0.1 in the univariate analysis. Furthermore, all cases were divided into two groups according to the qualitative variables that showed significant difference in the multivariate analysis, and the background factors were evaluated. [Results] The results of univariate analysis showed P < 0.1 for ‘Age’ and ‘Material of external auditory canal (EAC) packing’. Multivariate analysis showed P < 0.05 for both. The comparison between the two packing material groups showed that the gauze group was more likely to have improved hearing than Spongel? group, and the ossicular chain condition of the gauze group was maintained better. [Conclusion] ‘Age’ and ‘Material of EAC packing’ were considered to be significant factors affecting the postoperative hearing results. The selection and use of packing materials that provide stability should be considered to obtain better postoperative hearing results in type IV tympanoplasty. | |||||
書誌情報 |
Yonago Acta Medica en : Yonago Acta Medica 巻 63, 号 4, p. 313-318, 発行日 2020-11-24 |
|||||
雑誌内区分 | ||||||
値 | Original Articles | |||||
出版者 | ||||||
出版者 | Tottori University Medical Press | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 05135710 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00892882 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.33160/yam.2020.11.014 | |||||
権利 | ||||||
権利情報 | Yonago Acta medica 編集委員会 | |||||
情報源 | ||||||
関連名称 | Yazama Hiroaki, Watanabe Tasuku, Fujiwara Kazunori, et al. Factors Affecting Postoperative Hearing Results in Type IV Tympanoplasty: Preliminary Study of the Influence of External Auditory Canal Packing Material. 2020, 63(4). 313-318. doi:10.33160/yam.202 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/article/yam/63/4/63_2020.11.014/_article/ | |||||
関連名称 | https://www.jstage.jst.go.jp/article/yam/63/4/63_2020.11.014/_article/ | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.lib.tottori-u.ac.jp/yam/yam/yam63-4/63-4contents.html | |||||
関連名称 | http://www.lib.tottori-u.ac.jp/yam/yam/yam63-4/63-4contents.html | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
EISSN | ||||||
値 | 1346-8049 |