{"_buckets": {"deposit": "8b04adbb-62b3-485c-a1fe-b8ff12cdd1f8"}, "_deposit": {"created_by": 10, "id": "5027", "owners": [10], "pid": {"revision_id": 0, "type": "depid", "value": "5027"}, "status": "published"}, "_oai": {"id": "oai:repository.lib.tottori-u.ac.jp:00005027", "sets": ["12", "9", "1045"]}, "author_link": ["832", "18446", "18447", "2018", "18448", "18449"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "84", "bibliographicPageStart": "77", "bibliographicVolumeNumber": "52", "bibliographic_titles": [{"bibliographic_title": "Yonago Acta medica"}, {"bibliographic_title": "Yonago Acta medica", "bibliographic_titleLang": "en"}]}]}, "item_10001_checkbox_27": {"attribute_name": "部局名", "attribute_value_mlt": [{"subitem_checkbox_item": ["i-gakubu"]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To make clear the realities of indoor air (IA) pollution in lecture rooms of Tottori University in Japan, we studied air quality by monitoring the CO2 level, an index of IA pollution. We changed IA environment of lecture rooms while the lecture was given by using fan-ventilation or not, and with room doors open or closed: we monitored the CO2 level at 5-min intervals during 2 or 3 consecutive 90-min lectures using an infrared ray absorption type CO2 monitor. Based on the observed levels for 90 min, we calculated the ventilation rate (times of operating the ventilation fan), and estimated CO2 level change in ventilated and non-ventilated rooms for a 90-min lecture with the ventilation rate. In non-ventilated rooms, the observed and estimated CO2 level exceeded the maximum of 1,500 ppm specified by the Japanese Government. The excess was irrespective of the ratio of air volume/ person in non-ventilated rooms with doors closed. During the 1-h lunch break with doors open, over 5,000 ppm levels dropped below the standard. During the lecture in fan-ventilation, the CO2 level was decreased to below or near above the standard. Fan-ventilation during the lecture break reduced the level nearly to that in the outside air. In the case of no fan-ventilation during the following lecture(s), the level exceeded the standard. To maintain a clean air environment in highly airtight university lecture rooms, ventilation during lectures was crucial, which can be done effectively by the use of ventilation fans. Use of the estimated level is generally adaptive in promoting the use of ventilation fans.", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Tottori University Faculty of Medicine"}]}, "item_10001_relation_16": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Yonago Acta medica. 2009, 52(2), 77-84"}]}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Yonago Acta medica 編集委員会"}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00892882", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13468049", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_text_25": {"attribute_name": "EARMAS ID", "attribute_value_mlt": [{"subitem_text_value": "1130"}]}, "item_10001_text_29": {"attribute_name": "最新掲載誌名", "attribute_value_mlt": [{"subitem_text_value": "yam;Yonago Acta medica;Yonago Acta medica"}]}, "item_10001_text_32": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "Division of Medical Environmentology, Department of Social Medicine, School of Medicine, Tottori University Faculty of Medicine"}, {"subitem_text_value": "Department of Regional Environment, Faculty of Regional Sciences, Tottori University"}, {"subitem_text_value": "Wakayama Medical University School of Health and Nursing Science"}, {"subitem_text_value": "Department of Regional Environment, Faculty of Regional Sciences, Tottori University"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Houri, Daisuke"}, {"creatorName": "Houri, Daisuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "832", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40135877", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40135877"}, {"nameIdentifier": "100000242", "nameIdentifierScheme": "研究者総覧鳥取大学", "nameIdentifierURI": "http://researchers.adm.tottori-u.ac.jp/html/100000242_ja.html"}]}, {"creatorNames": [{"creatorName": "Kanazawa, Yousuke"}], "nameIdentifiers": [{"nameIdentifier": "18446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morioka, Ikuharu"}], "nameIdentifiers": [{"nameIdentifier": "18447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Kenji"}, {"creatorName": "Matsumoto, Kenji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "2018", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10073694", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10073694"}]}, {"creatorNames": [{"creatorName": "Kanazawa, Yousuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "18448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morioka, Ikuharu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "18449", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2009-07-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "52_077-084.pdf", "filesize": [{"value": "179.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "Yonago Acta medica 編集委員会", "licensetype": "license_note", "mimetype": "application/pdf", "size": 179600.0, "url": {"label": "52_077-084.pdf", "url": "https://repository.lib.tottori-u.ac.jp/record/5027/files/52_077-084.pdf"}, "version_id": "fbc0c34d-c2bb-439e-85b9-69eb8f33100f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "air quality", "subitem_subject_scheme": "Other"}, {"subitem_subject": "carbon dioxide", "subitem_subject_scheme": "Other"}, {"subitem_subject": "school environmental health", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ventilation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "air quality", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "carbon dioxide", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "school environmental health", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ventilation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Indoor Air Quality of Tottori University Lecture Rooms and Measures for Decreasing Carbon Dioxide Concentrations", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Indoor Air Quality of Tottori University Lecture Rooms and Measures for Decreasing Carbon Dioxide Concentrations", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "10", "path": ["12", "9", "1045"], "permalink_uri": "https://repository.lib.tottori-u.ac.jp/records/5027", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2018-06-22"}, "publish_date": "2018-06-22", "publish_status": "0", "recid": "5027", "relation": {}, "relation_version_is_last": true, "title": ["Indoor Air Quality of Tottori University Lecture Rooms and Measures for Decreasing Carbon Dioxide Concentrations"], "weko_shared_id": -1}
  1. 学部学科区分一覧
  2. 医学部・医学系研究科・医学部附属病院
  1. 資料タイプ一覧
  2. 学術雑誌論文
  1. 鳥取大学の刊行物
  2. Yonago Acta Medica
  3. 52
  4. 2

Indoor Air Quality of Tottori University Lecture Rooms and Measures for Decreasing Carbon Dioxide Concentrations

https://repository.lib.tottori-u.ac.jp/records/5027
https://repository.lib.tottori-u.ac.jp/records/5027
b9e0beb3-b9d6-43d8-acfb-4553613ed9ec
名前 / ファイル ライセンス アクション
52_077-084.pdf 52_077-084.pdf (179.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-06-22
タイトル
言語 en
タイトル Indoor Air Quality of Tottori University Lecture Rooms and Measures for Decreasing Carbon Dioxide Concentrations
言語
言語 eng
キーワード
主題 air quality
キーワード
主題 carbon dioxide
キーワード
主題 school environmental health
キーワード
主題 ventilation
キーワード
言語 en
主題 air quality
キーワード
言語 en
主題 carbon dioxide
キーワード
言語 en
主題 school environmental health
キーワード
言語 en
主題 ventilation
資源タイプ
資源タイプ journal article
著者 Houri, Daisuke

× Houri, Daisuke

WEKO 832
e-Rad 40135877
研究者総覧鳥取大学 100000242

Houri, Daisuke

en Houri, Daisuke

Search repository
Kanazawa, Yousuke

× Kanazawa, Yousuke

WEKO 18446

Kanazawa, Yousuke

Search repository
Morioka, Ikuharu

× Morioka, Ikuharu

WEKO 18447

Morioka, Ikuharu

Search repository
Matsumoto, Kenji

× Matsumoto, Kenji

WEKO 2018
e-Rad 10073694

Matsumoto, Kenji

en Matsumoto, Kenji

Search repository
Kanazawa, Yousuke

× Kanazawa, Yousuke

WEKO 18448

en Kanazawa, Yousuke

Search repository
Morioka, Ikuharu

× Morioka, Ikuharu

WEKO 18449

en Morioka, Ikuharu

Search repository
著者所属
Division of Medical Environmentology, Department of Social Medicine, School of Medicine, Tottori University Faculty of Medicine
著者所属
Department of Regional Environment, Faculty of Regional Sciences, Tottori University
著者所属
Wakayama Medical University School of Health and Nursing Science
著者所属
Department of Regional Environment, Faculty of Regional Sciences, Tottori University
抄録
内容記述タイプ Other
内容記述 To make clear the realities of indoor air (IA) pollution in lecture rooms of Tottori University in Japan, we studied air quality by monitoring the CO2 level, an index of IA pollution. We changed IA environment of lecture rooms while the lecture was given by using fan-ventilation or not, and with room doors open or closed: we monitored the CO2 level at 5-min intervals during 2 or 3 consecutive 90-min lectures using an infrared ray absorption type CO2 monitor. Based on the observed levels for 90 min, we calculated the ventilation rate (times of operating the ventilation fan), and estimated CO2 level change in ventilated and non-ventilated rooms for a 90-min lecture with the ventilation rate. In non-ventilated rooms, the observed and estimated CO2 level exceeded the maximum of 1,500 ppm specified by the Japanese Government. The excess was irrespective of the ratio of air volume/ person in non-ventilated rooms with doors closed. During the 1-h lunch break with doors open, over 5,000 ppm levels dropped below the standard. During the lecture in fan-ventilation, the CO2 level was decreased to below or near above the standard. Fan-ventilation during the lecture break reduced the level nearly to that in the outside air. In the case of no fan-ventilation during the following lecture(s), the level exceeded the standard. To maintain a clean air environment in highly airtight university lecture rooms, ventilation during lectures was crucial, which can be done effectively by the use of ventilation fans. Use of the estimated level is generally adaptive in promoting the use of ventilation fans.
書誌情報 Yonago Acta medica
en : Yonago Acta medica

巻 52, 号 2, p. 77-84, 発行日 2009-06
出版者
出版者 Tottori University Faculty of Medicine
ISSN
収録物識別子タイプ ISSN
収録物識別子 13468049
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA00892882
権利
権利情報 Yonago Acta medica 編集委員会
情報源
関連名称 Yonago Acta medica. 2009, 52(2), 77-84
著者版フラグ
出版タイプ VoR
戻る
0
views
See details
Views

Versions

Ver.1 2023-08-02 07:10:29.868422
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3